Philio
Smoke Sensor
PSG01
Notification Sensor
01
SD3502
6.51.02
0x013C (316)
0x0002 (2)
0x001E (30)
ZC10-14110003
2014-11-03 13:36:42.766832
N/A
Enhanced 232 Slave
Reporting Sleeping Slave
The Smoke Sensor PSG01 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-Wave technology.
The Smoke Sensor PSG01 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-Wave™ technology. It is a Z-Wave™ plus product, it supports the security, OTA... Those newest features of the Z-Wave™ technology. Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.

Product Picture
View configuration parameters (2)
7 - Customer Function
Customer function switch, using bit control. Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.Size: 1 byte
Default: 4
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 16 | 16 | Notification Type, Using Sensor Binary Report. |
| 0 | 0 | Notification Type, Using Notification Report. |
10 - Auto Report Battery Time
The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The value is in minutes.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 127 | The interval time for auto report the battery level. |
Operating instructions (4)
1. Have Z-Wave™ Controller entered inclusion mode. 2. Pressing button three times within 1.5 seconds to enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-Wave™ Controller about 20 seconds.
1. Have Z-Wave™ Controller entered exclusion mode. 2. Pressing button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed.
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing button four times within 1.5 seconds and do not release the button in the 4 th pressed, and the red LED will light ON. 2. After the red LED flash 9 times, release the button within 2 seconds. 3. IDs are removed and all settings will reset to factory default.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | PSG01_Manual.pdf |