Vision
Siren with DC adapter
ZM1602EU-5
Siren
02
ZM5202
6.51.06
0x0109 (265)
0x2009 (8201)
0x0907 (2311)
ZC10-15050007
2015-04-29 08:57:50.4286
N/A
Enhanced 232 Slave
Always On Slave
Siren will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z-Wave™ enabled network.
Features: *Loud audible alarm>105dB@1 meter *LED strobe lighting *Low battery detection *Siren for Battery Back-Up *100ft line of sight *LED Status Indicator *Operating temp: -15oC~60oC *Working Voltage: 6V *Dimensions: 116*77*40mm

Product Picture
View configuration parameters (2)
1 - Siren/Strobe mode
User can change value from 0 to 2 to turn either Siren sound, Strobe light, or both when triggered.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | All Enable - Default |
| 2 | 2 | Strobe Only |
| 1 | 1 | Siren Only |
2 - Alarm Auto Stop Time
User can change the duration of siren time when triggered.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 30 seconds - Default |
| 3 | 3 | Will Not Automatically Stop |
| 1 | 1 | 60 seconds |
| 2 | 2 | 120 seconds |
Operating instructions (4)
Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZM 1602 to your controller. To get in the “inclusion” mode, the distance between siren and controller is suggested to be in one meter. Open the bracket and press the program switch of ZM 1602 for 1 second at least & release to be included. After setting, the LED Setting Lighting should go off,
Set up the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZM 1602 from your controller. Press the Tamper Switch of ZM 1602 for 1 second at least & release to be excluded.
removing the back cover of the ZM1602 to get into “Awake” mode,
1. Support OTA firmware update from controller 2. Support Explorer Frame function
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | ZM 1602-5 Siren_R3_20170301.pdf |