Telldus
Plug-in Switch (Schuko)
TZWP-100
On/Off Power Switch
HW: 1 FW: 1.00
ZM5202
6.51.06
0x0176 (374)
0x0003 (3)
0x0001 (1)
ZC10-15115002
2015-11-10 12:31:38.981
N/A
Enhanced 232 Slave
N/A
Plug-in Switch
The slim design makes this plugin switch fit almost everywhere. You can even have two switches connected into a standard 2-way wall outlet at the same time. It has a repeater function for the Z-Wave network so you can extend the range of your smart home system. Easy to install and to include in the powerful Telldus Live! system. Control lights and other electronic devices up to 2300 W (resistive load). Option to turn off indication LED. 500 chip, Z-Wave Plus.

View configuration parameters (3)
1 - Countdown timer
Number of minutes before it auto-shuts down.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 254 | Minutes |
2 - Remember device status after power failure.
Define how the plug will react after the power supply is back on.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Always off |
| 1 | 1 | Remember status |
| 2 | 2 | Always on |
3 - LED indicator
Set the intensity of the LED indicatorSize: 1 byte
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Off |
| 1 | 100 | % |
Operating instructions (3)
Tripple click the button on the device
Tripple click the button on the device
Press and hold the button until the LED starts flashing white (approx. 6 seconds). Press the button once more, short. Please note! Only use the reset procedure when the primary controller is missing or inoperable.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | manual.pdf |