BeNeXt B.V.
Tag Reader 500
80820701.0
Other
HW: 20 FW: 1.00
ZM5101
6.61.00
0x008A (138)
0x0007 (7)
0x0200 (512)
ZC10-16105254
2016-10-04 08:13:28.4372
N/A
Enhanced 232 Slave
Reporting Sleeping Slave
Yes
A Tag Reader that bridges a RFID TAG to a Z-Wave message. In addition the Tag Reader has a numerical keypad which can be used to changes lifestyles or activate scenes.
A Z-Wave security enabled entry control device. You can arm/disarm your house to home or away with the Tag Reader 500. With the use of a RFID tag or a numerical code the device can send an entry control message which can be handled by a supported gateway. In addition the Tag Reader supports the activation of scenes.

Product Picture
View configuration parameters (7)
1 - Set to default
Set all configuration values to default values (factory settings). Read more in chapter Configuration Reset. All values except for 0x55 and 0xAA will default the other configurations valuesSize: 1 byte
Default: 170
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Default all |
| -1 | -1 | Default all |
2 - Feedback time
To configure the time the beep is automatically turned off in seconds. Value 0x00 means disable. Value between 0x01 and 0xFE is the time in seconds Value 0xFF means endless.Size: 1 byte
Default: 15
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 20 | 20 | 20 seconds |
| -1 | -1 | Endless |
3 - Feedback timeout
To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep is automatically sound. The error beeps are fixed 8 beeps shortly after each other. Value 0x00 means disable. Value between 0x01 and 0xFF is the time in secondsSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 2 | 2 | 2 seconds |
4 - Feedback beeps per second
To configure the number of beeps per second. Every beep is fixed about 10ms. Value between 0x00 and 0xFF are number of beeps per secondSize: 1 byte
Default: 2
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 8 | 8 | 8 beeps per seconds |
| 2 | 2 | 2 beeps per second |
5 - Always awake mode
To configure the always awake mode. Value 3: set to always awake mode Value any other then 3: set to normal operation modeSize: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Normal operation mode |
| 3 | 3 | Always awake mode |
7 - Operation mode
The mode that the TagReader communicates with the associated gateway. Value 0x00: The RFID and Numeric codes are reported in gateway mode Value 0x01 – 0xFF: the RFID and Numeric codes are reported in local modeSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Gateway mode |
| 1 | 1 | Local mode |
8 - Gateway confirmation
In gateway mode it is possible to let the gateway decide if the Tag Reader can arm to home or away. If gateway indication is disabled the Tag Reader automatically assumes that it can arm and will wait for a user input of RFID TAG or numeric code. Value 0x00: Gateway confirmation disabled Value 0x01 – 0xFF: Gateway confirmation enabledSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Gateway confirmation disabled |
| 1 | 1 | Gateway confirmation enabled |
Operating instructions (4)
To include the Tag Reader 500 press and hold the enter button for two seconds (indication LED blinks shortly). Release the enter button now to start the inclusion (during the include routine the indication LED will blink twice per second.
To exclude the Tag Reader 500 press and hold the enter button for two seconds (indication LED blinks shortly). Release the enter button now to start the exclusion (during the exclude routine the indication LED will blink three times per 1,5 second.
Press and hold the enter button for 7 seconds, the indication LED will go on for 1 full second.
The Tag Reader 500 has an option to reset it self to factory settings. Please use this procedure only when the network primary controller is missing or otherwise inoperable To reset the product to factory settings please do the following steps: 1. Press the enter button for 2 seconds, release the enter button to start the exclusion routine (indication LED will blink 3 times every second). 2. During the exclusion routine press enter button 4 times within 1,5 seconds to reset the product. 3. If ‘back to factory settings’ was successful the indication LED will go in for 1 full second on the end of the remove routine. 4. A DEVICE_RESET_LOCALLY_NOTIFICATION is sent to the nodes associated in the lifeline group.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | Quickstart_Technical_Manual_Tag_Reader500_v_0_9.pdf |
Features (3)
| Type | Value(s) |
|---|