Popp
Z-Wave CO Detector
POPE004407
Notification Sensor
HW: 1 FW: 1.00
ZM5202
6.51.06
0x0154 (340)
0x0004 (4)
0x0003 (3)
ZC10-16125332
2016-12-06 21:27:36.287588
N/A
Enhanced Slave
Reporting Sleeping Slave
Yes
This product combines a certified stand-alone Carbon Monoxide alarm with a plug-in Z-Wave module to form a wirelessly reporting Carbon Monoxide alarm. The Carbon Monoxide alarm is tested and certified by BSI to EN5029:2010.
The High-End Electro-Chemical Carbon Monoxide alarm head offers a 10 year sensor life and is powered via a 3V lithium battery that powers the Alarm head for the life of the alarm. The CO Sensor is monitored electronically and will report the following: 1. Alarm on Sensing Carbon Monoxide 2. Battery status reporting 3. Sensor Fault 4. Alarm removal from mounting plate 5. End of life to make sure it is replaced on time. The device is a secure Z-Wave Plus device and can be used in one wireless Z-Wave network with other certified devices regardless of origin and brand.

Product Picture
View configuration parameters (2)
1 - Value of On-Command
Size: 1 byte
Default: 99
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 99 | Basic Command Value |
2 - Value of Off-Command
Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 99 | Basic Command Value |
Operating instructions (4)
Pressing the button 'Inclusion Button' for one second will include the device. If the button is pressed for at least 2 seconds the inclusion will be done without the Security Command Class.
A single click on the button will exclude the device.
A single click on the button will wakeup the device.
To do a factory reset press the button on the bottom of the device for at least 10 seconds. This procedure should only be used when the primary controller is inoperable.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | 004407_en.pdf |
Features (2)
| Type | Value(s) |
|---|