FIBARO
FIBARO KeyFob
FGKF-601
Wall Controller
HW: 1 FW: 3.02
ZM5101
6.51.09
0x010F (271)
0x1001 (4097)
0x3000 (12288)
ZC10-17035483
2017-03-14 18:22:00.949278
N/A
Enhanced 232 Slave
Portable Slave
Yes
FIBARO KeyFob is a compact, battery-powered, Z-Wave remote.
FIBARO KeyFob is a Z-Wave Plus compatible, battery-powered, compact remote control. Six buttons allow you to control other devices through the Z-Wave network and run various scenes defined in FIBARO System. Configure actions for one, two, three clicks and holding the button to suit all your needs. Built-in locking system will ensure that unauthorized person will not take control of your home.

Product Picture
View configuration parameters (26)
1 - Lock Mode activation
This parameter allows to activate Lock Mode and set up unlocking sequence. Device will lock after time set in parameter 2 or after pressing and holding selected button. See "Lock Mode" on page 9 of the manual for more information. 0 - Lock Mode disabled 9-28086 - unlocking sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 9 | 28086 | unlocking sequence |
| 0 | 0 | Lock Mode disabled |
2 - Lock Mode - time to lock and locking button
This parameter allows to set time that must elapse from the last press of the button to lock the device and locking button. Setting locking button will deactivate associations and scenes for pressing and holding the selected button. This parameter is irrelevant if parameter 1 is set to 0 (Lock Mode disable). See "Lock Mode" on page 9 of the manual for more information. 0 - Lock Mode disabled 5-1791- calculated valueSize: 2 bytes
Default: 60
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Lock Mode disabled |
| 5 | 1791 | calculated value |
3 - First scene sequence
This parameter allows to set up sequence that activates scene with ID 7. See "Sequences" on page 10 of the manual for more information. 0 - 1st sequence disabled 9-28086 - value of sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 1 | sequence disabled |
| 9 | 28086 | value of sequence |
4 - Second scene sequence
This parameter allows to set up sequence that activates scene with ID 8. See "Sequences" on page 10 of the manual for more information. 0 - 1st sequence disabled 9-28086 - value of sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | sequence disabled |
| 9 | 28086 | value of sequence |
5 - Third scene sequence
This parameter allows to set up sequence that activates scene with ID 9. See "Sequences" on page 10 of the manual for more information. 0 - 3rd sequence disabled 9-28086 - value of sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 3 | sequence disabled |
| 9 | 28086 | value of sequence |
6 - Fourth scene sequence
This parameter allows to set up sequence that activates scene with ID 10. See "Sequences" on page 10 of the manual for more information. 0 - 4th sequence disabled 9-28086 - value of sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 4 | sequence disabled |
| 9 | 28086 | value of sequence |
7 - Fifth scene sequence
This parameter allows to set up sequence that activates scene with ID 11. See "Sequences" on page 10 of the manual for more information. 0- 5th sequence disabled 9-28086 - value of sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 9 | 28086 | value of sequence |
| 0 | 5 | sequence disabled |
8 - Sixth scene sequence
This parameter allows to set up sequence that activates scene with ID 12. See "Sequences" on page 10 of the manual for more information 0- 6th sequence disabled 9-28086 - value of sequenceSize: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 9 | 28086 | value of sequence |
| 0 | 6 | sequence disabled |
9 - Sequences - timeout
This parameter allows to set time that must elapse from the last press of the button to check if the sequence is valid. 5-30 (0.5-3s, 0.1s step) - time to lockSize: 1 byte
Default: 10
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 5 | 30 | time to lock |
| 0 | 0 |
10 - Single button associations - operating mode
This parameter allows to choose operating mode for single button associations. 0- single press switches state to opposite 1- single press switches state to opposite, double press sets to maximum level 2 - single press turns on, double press turns offSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | single press switches state to opposite |
| 1 | 1 | single press switches state to opposite, double press sets to maximum level |
| 2 | 2 | single press turns on, double press turns off |
11 - Value sent to □ association group
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them onSize: 2 bytes
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 99 | orcing level of associated devices |
| 255 | 255 | setting associated devices to the last remembered state or turning them on |
12 - Value sent to ○ association group
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them onSize: 2 bytes
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 99 | forcing level of associated devices |
| 255 | 255 | setting associated devices to the last remembered state or turning them on |
13 - Value sent to x association group
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them onSize: 2 bytes
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 99 | forcing level of associated devices |
| 255 | 255 | setting associated devices to the last remembered state or turning them on |
14 - Value sent to Δ association group
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them onSize: 2 bytes
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 99 | forcing level of associated devices |
| 255 | 255 | setting associated devices to the last remembered state or turning them on |
15 - Value sent to - association group
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them onSize: 2 bytes
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 255 | 255 | setting associated devices to the last remembered state or turning them on |
| 1 | 99 | forcing level of associated devices |
16 - Value sent to + association group
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. 1-99 - forcing level of associated devices 255 - setting associated devices to the last remembered state or turning them onSize: 2 bytes
Default: 255
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 99 | forcing level of associated devices |
| 255 | 255 | setting associated devices to the last remembered state or turning them on |
17 - Paired buttons association for □ and ○
This parameter allows to activate paired buttons association mode for □ and ○ buttons. Paired buttons are dependent and association are sent only to □ groups. ○ turns devices on and increases value, □ turns them off and decreases value. 0 - paired buttons association inactive 1- paired buttons association activeSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | paired buttons association inactive |
| 1 | 1 | paired buttons association active |
18 - Paired buttons association for x and Δ
This parameter allows to activate paired buttons association mode for x and Δ buttons. Paired buttons are dependent and association are sent only to x groups. Δ turns devices on and increases value, x turns them off and decreases value. 0 - paired buttons association inactive 1- paired buttons association activeSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | paired buttons association inactive |
| 1 | 1 | paired buttons association active |
19 - Paired buttons association for - and +
This parameter allows to activate paired buttons association mode for - and + buttons. Paired buttons are dependent and association are sent only to - groups. + turns devices on and increases value, - turns them off and decreases value. 0- paired buttons association inactive 1 - paired buttons association activeSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | paired buttons association inactive |
| 1 | 1 | paired buttons association active |
21 - Scene activation for □ button
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Held Down & Released NOTE Parameter 21 values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.Size: 1 byte
Default: 9
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Key Pressed 1 time |
| 2 | 2 | Key Pressed 2 times |
| 4 | 4 | Key Pressed 3 times |
| 8 | 8 | Key Held Down & Released |
22 - Scene activation for ○ button
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Held Down & Released NOTE Parameter 22 values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.Size: 1 byte
Default: 9
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Key Pressed 1 time |
| 2 | 2 | Key Pressed 2 times |
| 4 | 4 | Key Pressed 3 times |
| 8 | 8 | Key Held Down & Released |
23 - Scene activation for x button
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Held Down & Released NOTE Parameter 23 values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.Size: 1 byte
Default: 9
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Key Pressed 1 time |
| 2 | 2 | Key Pressed 2 times |
| 4 | 4 | Key Pressed 3 times |
| 8 | 8 | Key Held Down & Released |
24 - Scene activation for Δ button
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Held Down & Released NOTE Parameter 24 values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.Size: 1 byte
Default: 9
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Key Pressed 1 time |
| 2 | 2 | Key Pressed 2 times |
| 4 | 4 | Key Pressed 3 times |
| 8 | 8 | Key Held Down & Released |
25 - Scene activation for - button
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Held Down & Released NOTE Parameter 25 values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.Size: 1 byte
Default: 9
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Key Pressed 1 time |
| 2 | 2 | Key Pressed 2 times |
| 4 | 4 | Key Pressed 3 times |
| 8 | 8 | Key Held Down & Released |
26 - Scene activation for + button
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller. 1 - Key Pressed 1 time 2 - Key Pressed 2 times 4 - Key Pressed 3 times 8 - Key Held Down & Released NOTE Parameter 26 values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.Size: 1 byte
Default: 9
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Key Pressed 1 time |
| 2 | 2 | Key Pressed 2 times |
| 4 | 4 | Key Pressed 3 times |
| 8 | 8 | Key Held Down & Released |
29 - Associations in Z-Wave network security mode
Parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline” association group. 1 - 2nd group sent as secure 2 - 3rd group sent as secure 4 - 4th group sent as secure 8 - 5th group sent as secure 16 - 6th group sent as secure 32 - 7th group sent as secure 64 - 8th group sent as secure 128 - 9th group sent as secure 256 - 10th group sent as secure 512 - 11th group sent as secure 1024 - 12th group sent as secure 2048 - 13th group sent as secure NOTE Parameter 29 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.Size: 2 bytes
Default: 4095
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | 2nd group sent as secure |
| 2 | 2 | rd group sent as secure |
| 4 | 4 | 4th group sent as secure |
| 8 | 8 | 5th group sent as secure |
| 16 | 16 | 6th group sent as secure |
| 32 | 32 | 7th group sent as secure |
| 64 | 64 | 8th group sent as secure |
| 128 | 128 | 9th group sent as secure |
| 256 | 256 | 10th group sent as secure |
| 512 | 512 | 11th group sent as secure |
| 1024 | 1024 | 12th group sent as secure |
| 2048 | 2048 | 13th group sent as secure |
Operating instructions (4)
The Keyfob needs to be woken up to receive information about the new configuration from the Z-Wave controller, like parameters and associations. To wake up the device press O and + simultaneously or use 1st menu position: 1) Press O and – simultaneously. 2) Press Δ or X until LED glows white. 3) Press + to confirm.
Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. There are two ways of resetting the device: • Resetting using the menu 1) Press O and – simultaneously. 2) Press Δ or X until LED glows yellow. 3) Press + to confirm. • Resetting on start-up 1) Remove the battery. 2) Hold O and + while inserting the battery. Successful resetting will be confirmed by smoothly brightening and dimming of the yellow LED colour. Please use this procedure only when the network primary controller is missing or otherwise inoperable
1) Place the KeyFob within the direct range of your Z-Wave controller. 2) Set the main Z-Wave controller in (security/non-security) add mode (see the controller’s manual). 3) Press any button three times. 4) Wait for the adding process to end. 5) Successful adding will be confirmed by the Z-Wave controller’s message and green LED colour.
1) Place the KeyFob within the direct range of your Z-Wave controller. 2) Set the main Z-Wave controller in remove mode (see the controller’s manual). 3) Press O and – simultaneously. 4) Press Δ or X until LED glows green. 5) Press + to confirm. 6) Wait for the removing process to end. 7) Successful removing will be confirmed by the Z-Wave controller’s message.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | FGKF-601-EN-T-v1.0.pdf |
Features (4)
| Type | Value(s) |
|---|