FortrezZ LLC
Flood & Temperature Sensor
FTS05P
Notification Sensor
HW: 5 FW: 2.10
ZM5202
6.51.09
0x0084 (132)
0x00A3 (163)
0x020A (522)
ZC10-17065641
2017-06-07 22:52:41.580054
N/A
Enhanced 232 Slave
Reporting Sleeping Slave
Yes
Water damages are caused by leaking pipes and faulty appliances. Place sensors in areas near water consuming appliances. If a leak occurs, water will puddle and wet the sensor, triggering an alarm.
Gain the peace of mind and the protection you expect. Water damages are caused by leaking pipes, corroded water heaters, water storage tanks, fixtures in bathrooms, laundry rooms, refrigerator drip pans etc. Place this sensor in areas near water consuming appliances and drains. If a leak occurs, water will puddle and wet the sensor, triggering an alarm. The Sensor will notify the Z-wave controller that a flood has been detected. Paired with our Water Valve, these units will automatically signal the water to shut-off, eliminating any further damage from occurring.

Product Picture
View configuration parameters (4)
1 - Temperature Low threshold
Use this to change the low temperature alarm threshold. Set the range between -10 and 69 deg CSize: 1 byte
Default: 4
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 246 | 69 | -10 deg to 69 deg C |
2 - Temperature High threshold
Use this to change the high temperature alarm threshold. Set the range between -9 and 70 deg CSize: 1 byte
Default: 70
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 247 | 70 | -9 deg to 70 deg C |
3 - Normally Wet vs Normally Dry
Default is set as a Normally DRY sensor. Use this to switch to Normally WET sensor.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 240 | 0 or 240 |
4 - Water Alarm Association Mode
Use this to send basic set ON or Basic Set OFF when an alarm is detected. '240' is basic Set ON (default). Use value of '0' for sending basic set OFF when alarm detected.Size: 1 byte
Default: 240
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 240 | 0 | 240 or 0 |
Operating instructions (5)
1) Set up the Add/Inclusion mode at the controller; 2) Briefly press the switch once and the controller will indicate the unit has been added into the network. Also, the LED will blink 2 quick blinks when complete.
1) Set up the Remove/Exclusion mode at the controller; 2) Press and hold the switch for approx. 2 seconds and then release. The controller will indicates the unit has been removed from the network. The LED will blink 4 quick blinks when complete.
To initiate manual wakeup, press the program button once, while in network. Device stays awake for 10 seconds or longer if communicating with the controller.
Reset the device to factory Defaults - Press and hold the program button for longer than 15 seconds. When complete, the LED will flash approx. 30 times. This can be done while the device is either in or out of a network. Please use this procedure only when the network primary controller is missing or otherwise inoperable. Caution – When this is done in-network, the device will no longer be in the network and all configurations and associations will be set to default.
Over-the-Air (OTA) Firmware Update mode – If running on batteries, a firmware update should only be done with new batteries. Quickly press the program button 3 times while in-network and then activate your controller’s update mode. Caution – This should not be done unless a firmware update will be immediately started at the controller. Do not allow the OTA mode to continue indefinitely without starting the firmware update at your controller. Refer to your controller’s manual for update procedures. Press the button once to exit the OTA mode.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | User Manual FTS05-FTS05P.pdf |
Features (13)
| Type | Value(s) |
|---|
Supported notifications (4)
| Group | Type |
|---|---|
| Heat Alarm | (Refer to parameters): State idle |
| Water Alarm | (Refer to parameters): State idle |
| Power Management | (Refer to parameters): State idle |
| System | (Refer to parameters): State idle |
Supported sensors (5)
| Sensor type |
|---|
| Air Temperature |
| Humidity |
| Water Temperature |
| Soil Temperature |
| Moisture |