FAKRO
AMZ Z-Wave
AMZ
Window Covering - Pos/End Aware
HW: 31 FW: 1.01:01.01
ZM5202
6.61.00
0x0085 (133)
0x0005 (5)
0x0011 (17)
ZC10-17105794
2017-10-05 18:41:00.438822
N/A
Enhanced 232 Slave
Always On Slave
FAKRO AMZ Z-Wave is external awning blind, fully compatible white Z-Wave Plus protocol. Is dedicated for FAKRO roof window. The awning blind is powered by 15VDC.
FAKRO AMZ Z-Wave Electric awning blind is an appropriate combination of effective protection from heat and comfort of use. Due to the fact that the awning blind absorbs solar radiation before it reaches the glazing and emits the heat to the outside of the room, it constitutes much better protectction from tiresome heat in the sunny days than internal accessories. At the same time, it allows the ingress of natural light and ensures visual contact with the environment. FAKRO AMZ Z-Wave electrically is controlled by remote control or by wall switch in wireless system Z-Wave. In an emergency, the awning blind can be controlled by service button located on the awning blind. The awning blind is powered by 15VDC. Motor nominal current is 1.4A. The AMZ Z-Wave awning blind has three extremes: - Maximum extension (encoder maximum position) - Completely rolled up (encoder minimum position) - Current limiting protecting awning blind against damage and user against accidental injury resulting from the contact with moving elements of awning blind. There are three association groups in awning blind FAKRO AMZ Z-Wave: - Life Line – group for position reporting awning blind after each a stoppage and alarm reporting (overcurrent, damage encoders). This group can be a maximum 1 device. - Basic Repeat – group used to transfer the received basic commands to the devices included in this group. This group can be a maximum 5 devices. - Multilevel Repeat – group used to transfer the received multilevel commands to the devices included in this group. This group can be a maximum 5 devices. Technical Parameters: Power voltage: 15V DC Rated current: 1,4 A Current limit: YES Speed: 13 r.p.m Temperature of usage: (-10oC) do (65oC) Supplying cable: 2 x 0,75 mm2

Product Picture
View configuration parameters (2)
12 - Remote Calibration
This parameter is used to the remotly calibration of AMZ Z-Wave via gateway or remote control with a display, e.g. FAKRO ZRS24 Value 1 – calibrated Value 2 – discalibrated – to enter the calibration mode must first time discalibrate and then calibrateSize: 1 byte
Default: 1
Minimum: 1
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 2 | 1 – calibrated; 2 - discalibrated – to enter the calibration mode must first time discalibrate and then calibrate |
13 - Go to position
1 – FF go to maximum position 2 – FF go to previous positionSize: 1 byte
Default: 1
Minimum: 1
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 2 | 1 – go to maximum position; 2 – go to previous position |
Operating instructions (3)
Include - This function allow you to add awning blind to the network Z-Wave. Follow the procedur adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the awning blind for 1 second. Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power awning blind (OFF-ON-OFF-ON-OFF-ON) causes the introduction of awning blind to Autoinclusion mode. Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an awning to any Z-Wave controller running in the Include procedure.
Exclude - This function allow you to remove awning blind from the network Z-Wave. Follow the procedur removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the awning blind for 1 second. Function removes information only about newtork Z-Wave.
Device Reset Locally – This function allows you to reset the Z-Wave network without the use of Z-Wave controller. Press 5 times the programming button P fast, the awning blind was removed from the Z-Wave network, restore the default parameters, name and locations. Parameter Reset Locally – Press fast 3 times P button on the Awning Blind. Function removes information about parameters. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | 170206 AMZ Z-WAVE User Manual.pdf |
Features (9)
| Type | Value(s) |
|---|
Supported notifications (2)
| Group | Type |
|---|---|
| Power Management | (Refer to parameters): State idle |
| System | (Refer to parameters): State idle |