Vision
Power Monitor
ZL7261DE-5
On/Off Power Switch
HW: 2 FW: 24.02:33.00
ZM5202
6.81.00
0x0109 (265)
0x201A (8218)
0x1A06 (6662)
ZC10-18036064
2018-03-01 17:28:24.993518
N/A
Enhanced 232 Slave
Always On Slave
Power Monitor On/Off Module, German socket
This Power Monitoring On/Off Module is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave™ enabled network. Every main powered Z-Wave™ enabled device acts as a signal repeater and multiple devices result in more possible transmission routes, which helps eliminate “RF dead-spot”. Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled networks. This module will send On/Off signal to the appliance that attached to this module by receiving Z-Wave™ signal from controller or manually switch. It also sends the energy consumption to the controller when it requests. With special design, this module won’t interfere the other power outlet when plug into the AC outlet. This module also acts as repeater (supporting FLiRS).

Product Picture
View configuration parameters (2)
1 - Auto report timing
Automatic Meter Report interval for kWh/kVAhSize: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 120 | The number of minutes desired for automatic meter reports. |
2 - Report when Watt change
The change in watt consumption that will cause the transmission of voltage, current, and wattage to be sent.Size: 2 bytes
Default: 50
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 5 | 2300 | The number of watts change to cause reports to be sent. |
Operating instructions (4)
For “Inclusion” in (adding to) a network: Put the Z-Wave TM Interface Controller into “inclusion” mode, and following its instruction to add the ZL7261 into your controller. To get in the “Inclusion” mode. By power up to get included for first time, press the Program switch 3 times within 3 seconds to be included.
For “Exclusion” from (removing from) a network: Set up the Z-Wave TM Interface Controller into “exclusion” mode, and following its instruction to delete the ZL7261 from your controller. Press the Program Switch 3 times within 3 seconds to be excluded.
Reset: Press the Program Switch then power on (plug-in) and hold for 5 seconds before release the switch. Only use this procedure when the primary controller is lost or otherwise inoperable. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
The ZL7261 also supports energy metering, and meter information can be sent by the device to a listening controller automatically. For “Meter Supported Get” : the Z-Wave TM Interface Controller sends “Meter Get” then “Scale” command that see what kind of power consumption measurement want to report back according to the scales below. Then ZL7261 will report back the energy consumption values. Scale: 0x00-kWh; 0x01-kVAh 0x02-W 0X04-V 0X05-A 0X06-Power Factor Support OTA Firmware update from controller. Please refer to your controller manual. Once OTA function success, please make sure to exclusive the device & inclusive again before use the device.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | ZL7261-5_ Power Monitor_R0_20171129 (SDK6.81).pdf |
Feature (1)
| Type | Value(s) |
|---|
Supported meter (1)
| Meter type |
|---|
| Electric Meter Consumption |