Philio Technology
Smoke Sensor
PSG01
Notification Sensor
HW: 1 FW: 1.23:01.24
SD3502
6.51.02
0x013C (316)
0x0002 (2)
0x001E (30)
ZC10-18026006
2018-02-13 07:05:09.853272
N/A
Enhanced 232 Slave
Reporting Sleeping Slave
The Z-Wave Smoke Sensor PSG01 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-WaveTM technology
It is the Z-WaveTM plus Smoke Sensor, it supports security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.

View configuration parameters (2)
7 - Customer Function
Customer function switch, using bit control. Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.Size: 1 byte
Default: 4
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 4 | 4 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. |
10 - Auto Report Battery Time
The interval time for auto report the battery level. 0 means turn off auto report battery. Each tick means 30 minutes. The default value is 12(6 hours).Size: 1 byte
Default: 12
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 127 | The interval time for auto report the battery level. 0 means turn off auto report battery. Each tick means 30 minutes. The default value is 12(6 hours). |
Operating instructions (4)
1. Have Z-WaveTM Controller entered inclusion mode. 2. Pressing button three times within 1.5 seconds will enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds.
1. Have Z-WaveTM Controller entered exclusion mode. 2. Pressing button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed.
After the device is added to the network, it will wake-up once per day in default. When it wakes-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds to receive the setting commands. The wake-up interval minimum setting is 30 minutes, the maximum setting is 120 hours, the interval step is 30 minutes. If the user wants to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing button four times within 1.5 seconds and do not release the button in the 4th press, the red LED will light be ON. 2. After the red LED flash 9 times, release the button within 2 seconds. 3. IDs are removed and all settings will reset to factory default.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | PSG01_Manual-2015-06-12.pdf |
Features (2)
| Type | Value(s) |
|---|
Supported notifications (2)
| Group | Type |
|---|---|
| Smoke Alarm | State Idle |
| Home Security | (Refer to parameters): State idle |