COQON
Smart Power Adaptor Zwischenstecker
PSMZ0002
On/Off Power Switch
HW: 0 FW: 1.04
ZM5101
6.71.01
0x0140 (320)
0x0802 (2050)
0x1002 (4098)
ZC10-18086200
2018-08-03 21:11:37.412697
N/A
Enhanced 232 Slave
Always On Slave
Smart Power Adaptor with current power consumption measuring. The adaptor can be used for switching devices on and off under the use of the COQON Qbox or any other Z-Wave Controller.
The adaptor allows the remote controlled switching on and off of the connected electrical devices. It also measures current power consumption and total cumulative consumption. Increase your comfort: Wake up in the morning from the radio, the light goes on and the coffee machine is already preheated. Save energy costs: Disconnect power to your devices at the touch of a button or at a time you specify. - Save energy and costs.

Product Picture
View configuration parameters (11)
1 - Power Status
Status when power is powered upSize: 1 byte
Default: 2
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= OFF |
| 1 | 1 | 1= ON |
| 2 | 2 | 2= Status when last powered |
3 - Enable/disable Group 2 & 3
This allows enable/disable for Group 2&3Size: 1 byte
Default: 3
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Group 2 & 3 disable |
| 1 | 1 | 1= Group 2 enable |
| 2 | 2 | 2= Group 3 enable |
| 3 | 3 | 3= Group 2&3 enable |
5 - Over Voltage Alarm
Over Voltage Alarm (V)Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Over Voltage Alarm disabled |
| 1 | 260 | 1-260= Over Voltage Alarm Threshold |
6 - Over Current Alarm
Over Current Alarm (mA)Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Over Current Alarm disabled |
| 1 | 20000 | 1-20000= Over Current Alaram Threshold |
21 - Power Changes Report
Power Changes Sending ReportSize: 1 byte
Default: 10
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Power Sending Report disable |
| 1 | 100 | 1-100 = Power changes (%W) when report will be sent |
22 - Overload Power Report
Overload Power ReportSize: 2 bytes
Default: 3000
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Overload Report disable |
| 1 | 3680 | 1-3680 = 1-3680W |
23 - Energy Report
Energy Sending ReportSize: 2 bytes
Default: 1000
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Energy Report disable |
| 1 | 32767 | 1-32767= 1Wh to 32767 Wh |
24 - Meterin Report
Metering Report Time (second)Size: 2 bytes
Default: 3600
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= Metering Report disable |
| 1 | 32767 | 30-32767= Metering Report sent to lifeline |
25 - High Power Treshold
High Power Treshold (W)Size: 2 bytes
Default: 3000
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0= High Power Threshold disabled |
| 1 | 32767 | 1-32767= High Power Threshold |
26 - Low Power Threshold
Low Power Threshold (W)Size: 2 bytes
Default: 5
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Low Power Threshold disabled |
| 1 | 32767 | 1-32767= Low Power Threshold |
27 - Power Threshold Action
Power Threshold ActionSize: 1 byte
Default: 12
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Power Threshold Action disabled |
| 2 | 2 | Power High Threshold is enabled and send OFF to group 4 |
| 4 | 4 | Power High Threshold is enabled and send ON to group 4 |
| 8 | 8 | Power Low Threshold is enabled and send OFf to group 5 |
| 16 | 16 | Power Low Threshold is enabled and send ON to group 5 |
Operating instructions (3)
First start the COQON App. Select ""Device"" then ""Settings"" and tap on ""+"" to add yo ur Smart Plug. Select ""Add new COQON Device"" then scan the data code of the device or type in the product code manually and press Enter. Now follow the steps in the app and press ""inclusion"". After the 30 seconds countdown has started press the function key 3 times within 2 seconds to add the Device. Once connected, the Smart Plug LED will stop flashing.
First start the COQON App. Select the device you want to remove and tap on the trash can icon to start the ""exclusion"" process , then press ""exclude now"". After the 30 seconds countdown has started press the function key 3 times within 2 seconds to remove the Device.
To set the device back to factory default press the function key for 10 seconds. The LED will flash red 5 times and then turn off. Please use this procedure only when the primary controller is missing or inoperable.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | PSMZ0002 Manual NEW.pdf |
Features (5)
| Type | Value(s) |
|---|
Supported notification (1)
| Group | Type |
|---|---|
| Power Management | (Refer to parameters): State idle |
Supported meter (1)
| Meter type |
|---|
| Electric Meter Consumption |