Faultless
Electronic Z-Wave Deadbolt
A15-WG014-S2
Door Lock - Keypad
HW: 255 FW: 3.01:01.01
ZM5202
6.71.03
0x0262 (610)
0x0004 (4)
0x0002 (2)
ZC10-18096240
2018-09-25 21:26:35.162727
N/A
Enhanced Slave
Listening Sleeping Slave
Yes
An electronic touchscreen deadbolt with Z-Wave.
Great Convenience 。Touch to activate, touch to lock 。Connect your Z-Wave smart home system and operate from anywhere 。Holds up to 25 user codes 。Holds up to 4 single-entry codes 。Vacation mode (deactivates all user codes temporarily) 。Auto-lock with adjustable delay (10 - 99 seconds) 。Back-up mechanical keyway Uncompromised Security 。ANSI Grade 2 quality – deadbolt operates over 150,000 times 。ANSI A156.25 compliant - resistant to dust, rain, and corrosion under variable temperatures 。4-digit random guiding code prevents code-probing 。Touch screen is temporarily disabled after 4 consecutive incorrect entries Easy Installation 。Easy installation with a Philips screwdriver 。Fits most standard door preparations 。Online video instruction available (please scan the QR code on this box)

Product Picture
View configuration parameters (5)
1 - Guiding code on/off
Value 0X00=off 0x01=onSize: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 1 | 0X00=off 0x01=on |
2 - vacation mode on/off
Value 0X00=off 0x01=onSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 1 | 0X00=off 0x01=on |
3 - volume on/off
Value 0X00=off 0x01=onSize: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 1 | 0X00=off 0x01=on |
4 - auto-lock on/off
Value 0X00=off 0x01=onSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 1 | 0X00=off 0x01=on |
5 - auto lock timer 10-99
Value 0X0A~0X63 =10~99secondsSize: 1 byte
Default: 10
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 10 | 99 | 0X0A~0X63 =10~99seconds |
Operating instructions (3)
1. Press [SET] for 1 second 2. Enter 4 -8 digits programing Code 3. Press the buttons #90# 4. Include successfully (beep * 1) / unsuccessfully (beep x 3)
1. Press [SET] for 1 second 2. Enter 4 -8 digits programing Code 3. Press the buttons #90# 4. Exclusion successfully (beep * 1) /unsuccessfully (beep x 3)
1. Remove one battery 2. Press and hold SET button while inserting the battery back. Hold the set button until long beep has finished. 3. Restoring the lock to factory settings will remove its connection to your network and clear all devices from its association group. The reset procedure should only be used when the primary controller is missing or inoperable. 4.Please re-enter the default Programming Code to set up the lock after restoring to factory settings.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | manual-parameters.pdf |
Features (6)
| Type | Value(s) |
|---|
Supported notifications (2)
| Group | Type |
|---|---|
| Access Control | (Refer to parameters): State idle |
| Power Management | (Refer to parameters): State idle |