Zooz
Paddle Dimmer Switch
ZW313
Light Dimmer Switch
HW: 1 FW: 1.00
ZM5202
6.71.03
0x0312 (786)
0xA000 (40960)
0xA002 (40962)
ZC10-18106284
2018-10-30 00:01:09.514198
N/A
Enhanced 232 Slave
Always On Slave
It is an In-wall type device controlled by Z-Wave controller and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access .
It is an In-wall type device controlled by Z-Wave controller and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access, you can dim lights at home from your mobile phone separately, and manual dim light by push button .
Product Picture
View configuration parameters (11)
1 - Locally Button function
Locally Button functionSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | Up Button ON,Down Button OFF |
1 | 1 | Up Button OFF,Down Button ON |
2 - Status LED Configuration
Status LED ConfigurationSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | Output ON,Led OFF. |
1 | 1 | OutputOFF,Led ON. |
2 | 2 | Always OFF |
3 | 3 | Always ON |
4 - Count Down Configuration(Turn off the output by time)
Count Down Configuration(Turn off the output by time)Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | Auto Turn-OFF Timer Disabled |
1 | 1 | Auto Turn-OFF Timer Enabled |
0 | 65535 | Count Down Configuration(Turn off the output by time) |
5 - Enable Auto Turn-ON Timer
Enable Auto Turn-ON TimerSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | Auto Turn-ON Timer Disabled |
1 | 1 | Auto Turn-ON Timer Enabled |
6 - Count Down Configuration(Turn ON the output by time)
Count Down Configuration(Turn ON the output by time)Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 65535 | Count Down Configuration(Turn ON the output by time) |
7 - Association Setting Parameter
Association Setting ParameterSize: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | None |
1 | 1 | Local |
2 | 2 | 3-way |
3 | 3 | 3-way&ocal |
4 | 4 | Z-Wave Hub |
5 | 5 | Z-Wave Hub&Local |
6 | 6 | Z-Wave Hub &3-way |
7 | 7 | Z-Wave hub&Local&3-way |
8 | 8 | Timer |
0 | 0 | |
0 | 0 | |
9 | 9 | Timer&Local |
10 | 10 | Timer &3-way |
11 | 11 | Timer &3-way&Local |
12 | 12 | Timer&Z-Wave Hub |
13 | 13 | Timer&Z-Wave hub&Local |
14 | 14 | Timer&Z-Wave hub&3-way |
15 | 15 | All |
8 - Restores state after power failure
Restores state after power failureSize: 1 byte
Default: 2
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | Output OFF |
1 | 1 | Output ON |
2 | 2 | The state before a power outage. |
9 - Dimmer Speed Parameter
Dimmer Speed ParameterSize: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
1 | 99 | Dimmer Speed need xx S |
10 - Multilevel minimum value can be set(The minimum luminance value of the dimming)
Multilevel minimum value can be set(The minimum luminance value of the dimming)Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 99 | Multilevel minimum value can be set(The minimum luminance value of the dimming) |
11 - Multilevel maxmum value can be set(The maxmum luminance value of the dimming)
Multilevel maxmum value can be set(The maxmum luminance value of the dimming)Size: 1 byte
Default: 99
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 99 | Multilevel maxmum value can be set(The maxmum luminance value of the dimming) |
12 - when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness
when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightnessSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
From | To | Desription |
---|---|---|
0 | 0 | turn on to 99 |
1 | 1 | turn on to the value relate with parameter 11 |
Operating instructions (3)
Inclusion the ZW313 from the existing Z-Wave home control network with your primary controller. 1---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. 2---When prompted by your primary controller, click the Up or Down button three times in one second.
Exclusion the ZW313 from the existing Z-Wave home control network with your primary controller. 1---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. 2---When prompted by your primary controller, click the Up or Down button three times in one second.
Press click Z-Wave button 2 times quickly,and hold for at least 10 seconds. to restore the device to the factory Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Document (1)
Type | Name | |
---|---|---|
Product or Owner's Manual | 21-1-7-zen77-ver1.03-manual-curves.pdf |
Features (6)
Type | Value(s) |
---|