Alarm.com
Smart Thermostat
ADC-T3000
Thermostat - HVAC
HW: 8 FW: 1.20:01.20:01.20
ZM5202
6.81.03
0x0190 (400)
0x0006 (6)
0x0001 (1)
ZC10-19076575
2019-07-01 14:05:34.72273
N/A
Enhanced 232 Slave
Listening Sleeping Slave
Yes
The Alarm.com Intelligent Thermostat allows you to take remote control of your energy use and automate temperature settings — offering a new level of comfort.
The Alarm.com Intelligent Thermostat gives you remote access and control of your thermostat. Enjoy effortless energy management, climate and ambiance control, custom automation and measurable results. Create custom smart schedules that automate your thermostat. Receive critical temperature alerts to know instantly when your thermostat reaches preset limits. Save energy by using location-based automation to have your thermostat adjust itself while you're out. This thermostat is part of an entire ecosystem of home automation products. It was built to provide a single integrated solution to give you more from your connected home.

Product Picture
View configuration parameters (59)
1 - HVAC Type
HVAC System TypeSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Normal |
| 1 | 1 | Heat Pump |
2 - Number of Heat Stages
Number of heat stages if normal or the number of auxiliary heat stages if heat pumpSize: 1 byte
Default: 2
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 3 | Number of Heat Stages |
3 - Number of Cool Stages
Number of cool stages if normal or the number of heat pump stages if heat pumpSize: 1 byte
Default: 2
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 2 | Number of Cool Stages |
4 - Heat Fuel Type
Fuel type of heat source.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Fossil |
| 1 | 1 | Electric |
5 - Calibration Temp
Used to adjust the ambient room temperature reading up or down to a more accurate value. NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| -10 | 10 | Calibration Temperature |
6 - Swing
The number of degrees the thermostat will add (for COOL) or remove (for HEAT) to the target before turning the HVAC system on. The default resolution is 0.1F. NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 5
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 30 | Swing |
7 - Overshoot
The number of degrees the thermostat will keep the system on after meeting the system target. The default resolution 0.1F. NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 30 | Overshoot |
8 - Heat Staging Delay
In a multistage system, the number of minutes the thermostat will wait before turning on the next heating stage.Size: 1 byte
Default: 30
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 60 | Heat Staging Delay |
9 - Cool Staging Delay
In a multistage system, the number of minutes the thermostat will wait before turning on the next cooling stageSize: 1 byte
Default: 30
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 60 | Cool Staging Delay |
10 - Balance Setpoint
If the outside temperature falls below the balance setpoint, the thermostat will only use Auxiliary heating to heat and will not use the heat pump. NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 30
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 95 | Balance Setpoint |
12 - Fan Circulation Period
Size: 2 bytes
Default: 60
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1440 | Fan Circulation Period |
13 - Fan Circulation Duty Cycle
The percentage of the circulation period the fan is on.Size: 1 byte
Default: 25
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 100 | Duty Cycle |
14 - Fan Purge Time
The number of seconds the thermostat keeps the fan running after turning the system off.Size: 2 bytes
Default: 60
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 3600 | Fan purge time |
15 - Maximum Heat Setpoint
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 95
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 35 | 95 | Maximum Heat Setpoint |
16 - Minimum Heat Setpoint
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 35
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 35 | 95 | Minimum Cool Setpoint |
17 - Maximum Cool Setpoint
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 95
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 50 | 95 | Maximum Cool Setpoint |
18 - Minimum Cool Setpoint
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 50
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 35 | 95 | Minimum Cool Setpoint |
19 - Thermostat Lock
Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Full Lock |
| 2 | 2 | Partial Lock |
20 - Compressor Delay
Minimum interval in minutes the thermostat will keep the thermostat off after compressor cycle has finishedSize: 1 byte
Default: 5
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 60 | Minutes |
23 - Temperature Display Units
Size: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Celsius |
| 1 | 1 | Fahrenheit |
24 - HVAC Modes Enabled
Control which HVAC modes are enabled. Bitmask - Bit 0 - Off - Bit 1 - Heat - Bit 2 - Cool - Bit 3 - Auto - Bit 4 - Emergency HeatSize: 1 byte
Default: 15
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 3 | 3 | Off, Heat |
| 5 | 5 | Off, Cool |
| 7 | 7 | Off, Heat, Cool |
| 15 | 15 | Off, Heat, Cool, Auto |
| 31 | 31 | Off, Heat, Cool, Auto, Emergency Heat |
| 23 | 23 | Off, Heat, Cool, Emergency Heat |
| 19 | 19 | Off, Heat, Emergency Heat |
25 - Configurable Terminal Settings
Control the function of the configurable terminals, Z1 and Z2. Z1 is the first byte. Z2 is the second byte.Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | None |
| 1 | 1 | W3 |
| 2 | 2 | Humidifier |
| 3 | 3 | Dehumidifier |
26 - Power Source
READ ONLYSize: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| -128 | 127 | No Change - Read-Only Parameter |
27 - Low Battery Alert Threshold
Size: 1 byte
Default: 30
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 100 | Low Battery Alert Threshold |
28 - Very Low Battery Alert Threshold
28Size: 1 byte
Default: 15
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 100 | Very Low Battery Alert Threshold |
29 - Relay State
READ ONLY Bitmask of current relay state.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 65535 | Relay State |
30 - Remote temperature enable
Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Enabled |
31 - Heat Differential
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 30
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 10 | 100 | Heat Differential |
32 - Cool Differential
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 30
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 10 | 100 | Cool Differential |
33 - Temperature Reporting Threshold
NOTE: Temperature parameters take the form of 4-byte Z-Wave temperature commands where byte 1 is the (precision|scale|size) and bytes 2 and 3 are the 16-bit signed temperature value. Byte 4 is unused.Size: 4 bytes
Default: 10
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 5 | 20 | Temperature Reporting Threshold |
35 - Z-Wave Echo Association Reports
If enabled, thermostat will send reports for parameters changed from Z-Wave (e.g. thermostat setpoint).Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Enabled |
36 - C-Wire Power Thermostat Offset
Parameter to offset the local temperature measurement to account for internal self-heating from the C-Wire power supply. Only used when the thermostat detects C-Wire power is present.Size: 4 bytes
Default: 2
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 10 | Fahrenheit |
37 - Run Fan with Auxiliary Heat
If thermostat is configured as a heat pump at least one auxiliary heat source, this parameter determines if the thermostat will run the fan relay when auxiliary heating.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Enabled |
38 - Z-Wave Association Report Bitmask
• Bitmask to selectively enable non-required Z-Wave association reports. The report is enabled if the bit is set to one (1). Logically OR the values to together. o Bit 0 – Thermostat Mode o Bit 1 – Reserved o Bit 2 – Reserved o Bit 3 – Thermostat Operating State o Bit 4 – Thermostat Fan Mode o Bit 5 – Thermostat Fan State o Bit 6 – Ambient Temperature o Bit 7 – Relative Humidity o Bit 8 – Reserved o Bit 9 – Battery Low Notification o Bit 10 – Battery Very Low Notification o Bit 11- Thermostat Supported Modes o Bit 12 – Remote Enable Report o Bit 13 – Humidity Control Operating State Report o Bit 14 – HVAC Type o Bit 15 – Number of Cool/Pump Stages o Bit 16 – Number of Heat/Aux Stages o Bit 17 – Relay Status o Bit 18 – Power Source (C-Wire or Battery) o Bit 19 – Notification Report Power Applied o Bit 20 – Notification Report Mains Disconnected o Bit 21 – Notification Report Mains Reconnected o Bit 22 – Notification Report Replace Battery Soon o Bit 23 – Notification Report Replace Battery Now o Bit 24 – Notification Report System Hardware Failure o Bit 25 – Notification Report System Software Failure o Bit 26 – Notification Report System Hardware Failure with Code o Bit 27 – Notification Report System Software Failure with Code o Bit 28 – Display units (C/F) o Bit 29 – Heat Fuel Type o Bit 30 – Humidity Control Mode o Bit 31 – Humidity Control SetpointsSize: 4 bytes
Default: -1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Thermostat Mode bitmask |
| 8 | 8 | Thermostat Operating State bitmask |
| 16 | 16 | Thermostat Fan Mode bitmask |
| 32 | 32 | Thermostat Fan State bitmask |
| 64 | 64 | Ambient Temperature bitmask |
| 128 | 128 | Relative Humidity bitmask |
| 512 | 512 | Battery Low Notification bitmask |
| 1024 | 1024 | Battery Very Low Notification bitmask |
| 2048 | 2048 | Thermostat Supported Modes bitmask |
| 4096 | 4096 | Remote Enable Report bitmask |
| 8192 | 8192 | Humidity Control Operating State bitmask |
| 16384 | 16384 | HVAC Type bitmask |
| 32768 | 32768 | Number of Cool/Pump Stages |
| 65536 | 65536 | Number of Heat/Aux Stages bitmask |
| 131072 | 131072 | Relay Status bitmask |
| 262144 | 262144 | Power Source bitmask |
| 524288 | 524288 | Notification Report Power Applied bitmask |
| 1048576 | 1048576 | Notification Report Mains Disconnected bitmask |
| 2097152 | 2097152 | Notification Report Mains Reconnected bitmask |
| 4194394 | 4194394 | Notification Report Replace Battery Soon bitmask |
| 8388608 | 8388608 | Notification Report Replace Battery Now bitmask |
| 16777216 | 16777216 | Notification Report System Hardware Failure bitmask |
| 33554432 | 33554432 | Notification Report System Software Failure bitmask |
| 67108864 | 67108864 | Notification Report System Hardware Failure with code bitmask |
| 134217728 | 134217728 | Notification Report System Software Failure with Code bitmask |
| 268435456 | 268435456 | Display Units bitmask |
| 536870912 | 536870912 | Heat Fuel Type bitmask |
| 1073741824 | 1073741824 | Humidity Control Mode bitmask |
| -2147483648 | -2147483648 | Humidity Control Setpoint bitmask |
39 - Remote Temperature Timeout
Number of minutes before remote temperature is considered timed out and the thermostat will revert the local thermistor.Size: 2 bytes
Default: 130
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 32767 | minutes |
40 - Remote Temperature Differential
If difference between local thermistor and remote temperature exceeds this value, the thermostat will revert to the local thermistor.Size: 4 bytes
Default: 25
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 99 | Farhenheit |
41 - Remote Temperature ACK Failure Limit
If the thermostat fails to get an acknowledges for the specified value, it will revert to the local thermistor.Size: 1 byte
Default: 3
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 127 | Retries |
42 - Remote Temperature Display Enable
If enabled thermostat will show remote temperature on the UI. If disabled the thermostat will show the local temperature on the UI.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Enabled |
43 - Outdoor Temperature Timeout
Number of minutes before the outdoor timeout is considered timed out. This parameter is used for balance point.Size: 2 bytes
Default: 1440
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 32767 | Minutes |
45 - Heat Pump Expire
Number of minutes of running heat pump before the thermostat turns off the heat pump and only uses auxiliary heat. Setting this value to zero will disable the expiry.Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 2880 | Minutes |
46 - Dehumidify by AC Offset
The thermostat can use the AC to dehumidify. If the ambient temperature is within the offset and the relative humidity is above the dehumidify setpoint, the thermostat will use the AC to dehumidify.Size: 4 bytes
Default: 3
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 10 | Farhenheit |
48 - PIR Enable
If enabled, the thermostat will wake up the screen when motion is detected. This feature is only available when the thermostat is powered by C-Wire.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Enabled |
49 - Display Options
Bitmask to control various display features. - Bit 0 - Display humidity along with setpoint when not in off mode.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Do not show Humidity |
| 1 | 1 | Show Humidity |
50 - System Configuration
Read Only System ConfigurationSize: 4 bytes
Default: 0
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| -2147483648 | 2147483647 | No Change - Read-Only Parameter |
51 - Thermostat Reset
Remote reset of the thermostat. Must write the magic value (0x03B6). This is the same as power cycling the thermostat. It does not reset any parameters.Size: 2 bytes
Default: 2870
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 2870 | 2870 | Magic Value |
52 - Vent Options
Size: 1 byte
Default: 4
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disabled |
| 1 | 1 | Always activate regardless of thermostat operating state |
| 2 | 2 | Only activate vent when the thermostat operating state is heating. |
| 3 | 3 | Only activate vent when the thermostat operating state is cooling |
| 4 | 4 | Only activate vent when the thermostat operating state is heating or cooling |
53 - Vent Circulation Period
Size: 2 bytes
Default: 60
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 10 | 1440 | Minutes |
| 0 | 0 | Disabled |
54 - Vent Circulation Duty Cycle
Size: 1 byte
Default: 25
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 100 | Duty Cycle |
55 - Vent Maximum Outdoor Temperature
Vent is disabled if outdoor temperature exceeds this value. Setting this value to -1 disables the limit.Size: 4 bytes
Default: -1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| -1 | -1 | Disabled |
| 0 | 99 | Fahrenheit |
56 - Vent Minimum Outdoor Temperature
Vent is disabled if outdoor temperature exceeds this value. Setting this value to -1 disables the limit.Size: 4 bytes
Default: -1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| -1 | -1 | Disabled |
| 0 | 99 | Fahrenheit |
57 - Relay Harvest Level
Size: 1 byte
Default: 12
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Off |
| 9 | 9 | 8 Pulses |
| 10 | 10 | 16 Pulses |
| 11 | 11 | 32 Pulses |
| 12 | 12 | 64 pulses |
58 - Relay Harvest Interval
Size: 1 byte
Default: 4
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Off |
| 2 | 2 | 4 Milliseconds |
| 3 | 3 | 8 Milliseconds |
| 4 | 4 | 16 Milliseconds |
| 5 | 5 | 32 Milliseconds |
59 - Minimum Battery Reporting Interval
Size: 1 byte
Default: 6
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 127 | Hours |
60 - Humidity Control Swing
Size: 1 byte
Default: 5
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 100 | Percent Relative Humidity |
61 - Minimum Humidity Reporting Threshold
Size: 1 byte
Default: 5
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 100 | Percent Relative Humidity |
62 - Z-Wave Send Fail Limit
If thermostat experiences successive Z-Wave Transmit ACK failures exceeding the limit, the thermostat will not attempt any more unsolicited association reports until it receives a successful acknowledge for an association report. If this value is zero, the ACK failure limit is disabled.Size: 1 byte
Default: 10
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 127 | Send Failures |
| 0 | 0 | Disabled |
63 - Z-Wave Listen Before Talk Threshold
Set the listen before talk threshold on the thermostat. The threshold controls at what RSSI level the Z-Wave radio will refuse to transmit because of noise. Each step corresponds to a 1.5dB power step. Byte 0 is the LBT threshold for channel 0 and Byte 1 is the LBT threshold for channel 1.Size: 2 bytes
Default: 2046
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 32767 | Listen before talk threshold |
64 - Vent Override Lockout
Size: 1 byte
Default: 12
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 127 | Hours |
65 - Humidify Options
Size: 1 byte
Default: 1
Minimum: 0
Maximum: 0
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Always humidify regardless of thermostat operating state |
| 1 | 1 | Only humidify when the thermostat operating state is heating, when in heat mode, or when heating in auto mode. When the thermostat is in any other mode, the thermostat will humidify whenever it is necessary. |
Operating instructions (3)
1. Put Z-Wave controller into Add mode. See Z-Wave controller documentation for further documentation. 2. Press the Menu (-) Button 3. Select SETTINGS 4. Select NETWORK 5. Select ADD 6. Thermostat will display ‘Network Add In Progress’ and the 4-digit DSK pin. The pin can be used for S2 inclusion. 7. The thermostat has been added successfully when the thermostat displays ‘Network Add Complete’
1. Put Z-Wave controller into Remove mode. See Z-Wave controller documentation for further documentation. 2. Press the Menu (-) Button 3. Select SETTINGS 4. Select NETWORK 5. Select REMOVE 6. Thermostat will display ‘Network Remove In Progress’. 7. The thermostat has been removed successfully when the thermostat displays ‘Network Remove Complete’
Please use this procedure only when the network primary controller is missing or otherwise inoperable. 1. Turn the display on with any button press 2. Press Menu (-) button to go to main menu 3. Select SETTTINGS. 4. Select CONTINUE when prompted with the warning. 5. Select RESET 6. Select YES when prompted with the reset confirmation question. 7. Select CONTINUE when prompted with the network reset question.
Document (1)
| Type | Name | |
|---|---|---|
| Product or Owner's Manual | T3000_user_guide_190630.pdf |
Features (25)
| Type | Value(s) |
|---|
Supported notifications (2)
| Group | Type |
|---|---|
| Power Management | (Refer to parameters): State idle |
| System | (Refer to parameters): State idle |
Supported sensors (2)
| Sensor type |
|---|
| Air Temperature |
| Humidity |