GE
Smart Flood/Freeze Sensor
38959/ZW6306
Notification Sensor
HW: 255 FW: 5.54
ZM5101
6.81.03
0x0063 (99)
0x4953 (18771)
0x3231 (12849)
ZC10-19096758
2019-09-24 17:19:41.618911
N/A
Enhanced 232 Slave
Always On Slave
Yes
Heighten your senses with the Enbrighten Z-Wave Plus Flood/Freeze Sensor. When paired with a compatible hub, the smart sensor provides notification when water levels or temperatures change. Z-Wave devices can also be activated wirelessly for increased convenience and peace of mind.
Heighten your senses with the Enbrighten Z-Wave Plus Flood/Freeze Sensor. When paired with a compatible hub, the smart sensor provides notification when water levels or temperatures change. Z-Wave devices can also be activated wirelessly for increased convenience and peace of mind. Your automation possibilities are seemingly infinite when connected to hubs from Wink, SmartThings, HomeSeer, Vera, Nexia and more. • Trigger events – The sensor communicates with your hub to initiate desired actions of Z-Wave devices. Increase peace of mind by automatically turning on lights, sending a notification to your phone, activating an alarm or more when temperatures or water levels change. • Detection alarm – Built-in speaker emits audible alert when water levels or temperatures change to allow immediate action by anyone in the area. • Dual function – Base contacts and a detachable probe accommodate various setups. Recessed contacts on the base of the sensor are ideal for placement on flat surfaces. The included probe extends reach for use in wells, sump pump holes and other small spaces. • Temperature sensor – In temperature-sensitive spaces, protect against costly damage caused by freezing or overheating. • Indicator light – LED indicator displays status and provides feedback during programming. It also serves as notification if tampering with the sensor occurs. • Universal compatibility – Z-Wave Plus and all previous Z-Wave generations work together to allow continued expansion of your home-automation network.

Product Image
View configuration parameters (8)
19 - Alternate Exclusion
Size: 2 bytes
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Press the button once when prompted to remove device. |
| 1 | 1 | Press the button three times quickly when prompted to remove device. |
21 - Reverse Detection of Wet/Dry
ONLY use with included probe.Size: 2 bytes
Default: 1
Minimum: 1
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Normal detection(water detected) |
| 2 | 2 | Reverse detection(dry detected) |
22 - Temperature Report Interval (When battery operated)
Size: 2 bytes
Default: 60
Minimum: 5
Maximum: 1440
Possible values
| From | To | Desription |
|---|---|---|
| 5 | 60 | 5...60 Minutes |
| 60 | 60 | (Default) - Hourly |
| 360 | 360 | 6 Hours |
| 720 | 720 | 12 Hours |
| 1440 | 1440 | Daily |
23 - Battery Report Interval
Size: 2 bytes
Default: 1440
Minimum: 5
Maximum: 1440
Possible values
| From | To | Desription |
|---|---|---|
| 5 | 60 | 5...60 Minutes |
| 360 | 360 | Hourly |
| 720 | 720 | 12 Hours |
| 1440 | 1440 | (Default) - Daily |
50 - Low Temp Alarm
Notification type: Heat = 04 Under limit event = 06 Under limit non-event = 00Size: 2 bytes
Default: 33
Minimum: -4
Maximum: 122
Possible values
| From | To | Desription |
|---|---|---|
| -4 | 122 | -4F to 122F |
51 - High Temp Alarm
Notification type: Heat = 04 Over limit event = 02 Over limit non-event = 00Size: 1 byte
Default: 104
Minimum: -4
Maximum: 122
Possible values
| From | To | Desription |
|---|---|---|
| -4 | 122 | -4F to 122F |
52 - Temperature Report Interval (When USB operated)
Size: 2 bytes
Default: 60
Minimum: 5
Maximum: 360
Possible values
| From | To | Desription |
|---|---|---|
| 5 | 360 | 5…360 Minutes - Sent every 5 minutes, up to 6 hours |
| 60 | 60 | Hourly |
53 - Tamper Alert Configuration
Size: 1 byte
Default: 1
Minimum: 1
Maximum: 5
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | (Default) - Red LED continuous flash and beeps |
| 2 | 2 | Red LED flashes once, continuous beeps |
| 3 | 3 | Red LED continuous flash, no beeps |
| 4 | 4 | Red LED flash once, no beeps |
| 5 | 5 | No LED, no beeps |
Operating instructions (5)
1. Follow the instructions for your Z-Wave certified controller to add the sensor in the Z-Wave network. 2. Once the controller is ready to add your device, remove the top cover of the sensor. Ensure battery is installed with the correct polarity and the battery tab has been removed, or ensure micro USB is plugged into USB port. 3. Press and release the programming button (see figure 10). This starts the manual add process. The red LED flashes quickly as it searches for a network. After 25 seconds, the LED will stop flashing. Press the programming button to manually start the add process. If it times out, the LED will stop flashing. Press and release the programming button again. 4. The controller's app will indicate if it discovers the sensor. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box or the QR code label on the product (see above). Enter the 5-digit code. 5. The red LED will activate for 3 seconds to confirm the sensor has been added in the network. 6. Secure the top cover into place.
1. Follow the instructions for your Z-Wave certified controller to remove the sensor from the Z-Wave network. 2. Once the controller is ready to remove your sensor, press and release the programming button one time on the sensor (see figure 10). 3. The red LED will blink five times to indicate it has been removed. Secure the top cover.
Press and release the programming button one time on the sensor (see figure 10).
1. Press the programming button 10 times within 6 seconds (interval between presses of the button cannot be longer than 1 second). 2. The red LED will activate for 2 seconds, followed by three quick flashes. This confirms the sensor has been reset. Secure the top cover into place. Note: This should only be used if your network’s primary controller is missing or otherwise inoperable.
If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box or the QR code label on the product.
Documents (2)
Features (2)
| Type | Value(s) |
|---|
Supported notification (1)
| Group | Type |
|---|---|
| Water Alarm | Sensor status: Water leak detected |
Supported sensor (1)
| Sensor type |
|---|
| Air Temperature |