Ness Z-Wave™ Door Strike Controller
ZU-116001
Lock DT
HW: 01 FW: 01.03
ZGM130S037HGN2 / ZGM130S037HGN1
7.15.4
0x0189 (393)
N/A
0x0204 (516)
ZC14-22030071
2022-03-02 12:48:07
N/A
Enhanced 232 Slave
Listening Sleeping Slave
Ness Z-Wave™ Door Lock Controller (DLC) is a unique access control accessory providing a smart relay output and door position sensor inputs.

View configuration parameters (6)
1 - The Relock Timer
Sets the output duration for the RELAY Output and the 12V Lock Output. Output ON duration in seconds. Range: 0 ~ 300. Default: 10 0 = Latching OperationSize: 2 bytes
Default: 10
Minimum: 0
Maximum: 300
Possible values
Not available
2 - Function Options for Input Terminal SW1
Range:0 ~ 3. Default: 2Size: 1 byte
Default: 2
Minimum: 0
Maximum: 3
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | The input is disabled |
| 1 | 1 | Normally Closed Door sensor |
| 2 | 2 | Normally Open Door sensor |
| 3 | 3 | External unlock pushbutton input (close circuit to unlock) |
3 - Function Options for Input Terminal SW2
Range:0 ~ 3. Default: 3Size: 1 byte
Default: 3
Minimum: 0
Maximum: 3
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | The input is disabled |
| 1 | 1 | Normally Closed Door sensor |
| 2 | 2 | Normally Open Door sensor |
| 3 | 3 | External unlock push button input (close circuit to unlock) |
4 - Battery Low Setting
Reporting the battery low warning message when battery level reaches this value in percentage. Range:10 ~ 50 (10% to 50%) Default: 10%Size: 1 byte
Default: 10
Minimum: 10
Maximum: 50
Possible values
Not available
5 - Battery Scheduled Report Interval
The battery level scheduled report interval time is based on every 30 minutes per kick. The value N related to the time in minutes is Nx 30minutes. Range: 0~120. Default: 12 (12x30 =360minutes). Value = 0 Disable Battery level scheduled report.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 120
Possible values
Not available
6 - The 12V DC Power Output Options
This parameter is used to enable/disable the 12V DC power output at the power output terminal. Range: 0~1. Default: 0Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | The power output is disabled. |
| 1 | 1 | The power output is enabled. |
Operating instructions (5)
To add the device into the Z-Wave™ network: 1) Power on device and ensure it has been factory defaulted. 2) Set the primary controller into inclusion mode. 3) Click the Action Button once the device enters the inclusion mode and the Red LED starts fast flashing. Note: Inclusion mode can be cancelled by clicking the Action Button once again before the device starts the learning process (controller has not yet started inclusion mode), the device exits the learning mode and Red LED stops fast flash. 4) The inclusion is processing. 5) If your Z-Wave controller supports S2 Access encryption and DSK, enter the first 5 digits of the DSK located at bottom of the QR image. 6) If the inclusion is successful, the Red LED stops fast flashing and the Green LED turns on for 2 seconds.
You may need to refer to your Z-Wave™ gateway’s instructions for removing devices. Exclusion To remove the device from the Z-Wave network: 1) The device is powered 2) Set the primary controller into exclusion mode. 3) Click the Action Button once the device enters the inclusion mode and the Red LED starts fast flashing. Click the Action Button once again before the device starts the learning process (controller has not yet started inclusion mode), the device exits the learning mode and Red LED stops fast flash. 4) If the exclusion is successful, the Red LED stops flashing and the Green LED turns on for 1 second.
Not required. The product is always awake.
To Factory Default Ness Z-Wave DLC Please use this procedure only when the network primary controller is missing or otherwise inoperable. Reset the device to factory Default: 1) The device is powered 2) Press and hold the action button down for 20 seconds. When the action button has been held for greater than 3 seconds, the Red LED starts fast flash, and the Fast flash will stop after 20 seconds. Once the action button is released, the Green LED will turn on for 1 second indicating that the device has been reset. 3) Release the action button while the Red LED is fast flashing (before 20 seconds), the device reset will be cancelled, and the Red LED will stop fast flash.
Page 8. Ness Z-Wave DLC is a SmartStart enabled device allowing it to be added into a Z-Wave network by scanning its Z-Wave QR Code with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. *Requires a SmartStart compatible controller and app. Ness Z-Wave DLC must be within network range.
Document (1)
| Type | Name | |
|---|---|---|
| Unknown | 890-501_ZWave_DLC_Manual_draft10.pdf |
Feature (1)
| Type | Value(s) |
|---|
Supported notifications (2)
| Group | Type |
|---|---|
| Access Control |
|