Philio
4 in 1 Multi-Sensor
PST10-ANZ
Notification Sensor DT
HW: 01 FW: 01.01:01.01
ZGM130S037HGN2 / ZGM130S037HGN1
7.15.1
0x013C (316)
N/A
0x0002 (2)
ZC14-21110019
2021-11-19 14:38:08
N/A
Enhanced 232 Slave
Reporting Sleeping Slave
The 4 in 1 multi-sensor PST10 has PIR, door/window, temperature and light sensor for combining several functionalities in one device.

View configuration parameters (15)
1 - Basic Set Level
Setting the BASIC cmd value.Size: 1 byte
Default: 99
Minimum: 0
Maximum: 99
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
2 - Auto Report Door/Window State
Interval time door/window.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 127
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
3 - PIR Sensitivity
PIR sensitivity settings.Size: 1 byte
Default: 99
Minimum: 0
Maximum: 99
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
4 - Operation Mode
Operation mode.Size: 1 byte
Default: 49
Minimum: 0
Maximum: 255
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
5 - Customer Function
Customer function switch.Size: 1 byte
Default: 3
Minimum: 0
Maximum: 255
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
6 - PIR Re-Detect Interval Time
PIR re-detect time.10 s tickSize: 1 byte
Default: 6
Minimum: 1
Maximum: 60
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
7 - Turn Off Light Time
Delay time PIR detected.Size: 1 byte
Default: 7
Minimum: 1
Maximum: 60
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
8 - Auto Report Battery Time
Interval time battery level.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 127
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
9 - Auto Report LightSensor Time
Interval time illumination.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 127
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
10 - Auto Report Temperature Time
Interval time temperature.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 127
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
11 - Auto Report Tick Interval
Interval time report tick.Size: 1 byte
Default: 30
Minimum: 0
Maximum: 255
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
12 - Temperature Differential Report
temperature differential.Size: 1 byte
Default: 10
Minimum: 1
Maximum: 100
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
13 - LightSensor Differential Report
LightSensor Differential.Size: 1 byte
Default: 20
Minimum: 1
Maximum: 100
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
14 - PIR Trigger Mode
PIR Trigger Mode.Size: 1 byte
Default: 1
Minimum: 1
Maximum: 3
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
15 - PIR NightLine
PIR night Lux conditions.Size: 2 bytes
Default: 2
Minimum: 1
Maximum: 10000
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
Operating instructions (5)
1. Have Z-WaveTM Controller entered inclusion mode. 2. Pressing tamper key three times within 2 seconds to enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
1. Have Z-WaveTM Controller entered exclusion mode. 2. Pressing tamper key three times within 2 seconds to enter the exclusion mode. Node ID has been excluded.
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum se
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing button four times and keep about 5 seconds. 2. IDs are excluded and all settings will reset to factory default.
1. Product has a DSK string, you can key in first five digit to increment smart start process, or you can scan QR code. 2. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a control
Document (1)
| Type | Name | |
|---|---|---|
| Unknown | PST10_UserManual_V6.2.pdf |
Features (2)
| Type | Value(s) |
|---|
Supported notification (1)
| Group | Type |
|---|---|
| Home Security | Motion sensor status: Motion detection |
Supported sensors (2)
| Sensor type |
|---|
| Air Temperature |
| Illuminance |