Philio
Smart Energy Plug
PAN44_US
Binary Switch DT
HW: 01 FW: 01.01
ZGM130S037HGN2 / ZGM130S037HGN1
7.16.3
0x013C (316)
N/A
0x0001 (1)
ZC14-22030078
2022-03-16 12:53:53
N/A
Enhanced 232 Slave
Always On Slave
PAN44 is a Smart Energy Plug. The built-in power meter can let you monitor the power consumption of your electric appliances. The product supports an Over the Air (OTA) feature for the products firmware upgrade.

View configuration parameters (9)
1 - Watt Meter Report Period
If the setting is configured for 1hour (set value =720), the PAN44 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). If the setting value is 0, the auto report function ofmeter Watt will be disabled.Size: 2 bytes
Default: 720
Minimum: 0
Maximum: 32767
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable Watt Report |
| 1 | 32767 | 5s~45h |
2 - KWH Meter Report Period
If the setting is configured for 1hour (set value =6), the PAN44 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). If the setting value is 0, the auto report function of meter KWh will be disabled.Size: 2 bytes
Default: 6
Minimum: 0
Maximum: 32767
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable KWh Report |
| 1 | 32767 | 10min~227days |
3 - Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if thesetting value is 750, when the load current of Relay1 or Relay2 over this value, PAN44 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.Size: 2 bytes
Default: 1300
Minimum: 10
Maximum: 1300
Possible values
| From | To | Desription |
|---|---|---|
| 10 | 1300 | N * 0.01A, 1300*0.01A = 13A |
4 - Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN44 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.Size: 2 bytes
Default: 10000
Minimum: 1
Maximum: 10000
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 10000 | 1KWh, 10000*1KWh = 10000 KWh |
5 - Restore switch state mode
Whenever the AC power return from lost, PAN44 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Switch off |
| 1 | 1 | Last switch state |
| 2 | 2 | Switch on |
6 - Mode of Switch Off function
When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the Off function of include button will be disabled. The default setting is enable mode. When manual On/Off function is disabled, the RF command and include button can only switch On but not Off. This is useful function for keeping the device in switch on state.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
7 - LED indication mode
LED indication mode: The default setting is Show Switch State. 3-7-1 Show Switch State: When switch is on, LED is on. When switch is off, LED is off. 3-7-2 Show Night mode: When switch is on, LED is off. When switch is off, LED is on. 3-7-3 One Flash mode: When the state of switch changes, LED will be on only one second, then LED keeps off.Size: 1 byte
Default: 1
Minimum: 1
Maximum: 3
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 1 | Show switch state |
| 2 | 2 | Show night mode |
| 3 | 3 | One flash mode |
8 - Watt differential report mode
Whenever Watt value of PAN44 changes over 5% of last reading value, it will send Meter report to the group 1 nodes. However, if Watt differential mode as 0, the unsolicited report will be disabled.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 4
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | 5% |
| 2 | 2 | 10% |
| 3 | 3 | 15% |
| 4 | 4 | 20% |
9 - Switch status report mode
Whenever PAN44 manually switch on or off, it will send BINARY_SWITCH_ REPORT to the node of group1, disable when set to 0.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
Operating instructions (4)
1. Put your Z-Wave™ controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Press the on/off button three times within two seconds to enter inclusion mode.
1. Put your Z-Wave™ controller into exclusion mode by following the instructions provided by the controller manufacturer. 2. Press the on/off button three times within two seconds to enter exclusion mode. 3. Node ID will be excluded.
1. Press the on/off button three times within two seconds. 2. Within 1 second, press on/off button again last for 5 seconds. 3. Device has been reset.
1. The product has a DSK string. Key in the first five digits to initiate the SmartStart process, or scan QR code. 2. SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code on the product, with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically to the closest network within 10 minutes of being switched on.
Document (1)
| Type | Name | |
|---|---|---|
| Delete reset column bold "1." on page 3 | PAN44_MANU_20220315.pdf |
Features (2)
| Type | Value(s) |
|---|
Supported notifications (2)
| Group | Type |
|---|---|
| Power Management |
|