Zooz
700 Series Outdoor Double Plug
ZEN14
On/Off Power Switch
HW: 255 FW: 1.01
ZM5202
6.71.01
0x027A (634)
0x7000 (28672)
0xB003 (45059)
ZC10-22087116
2022-08-08 13:28:53.766777
N/A
Enhanced 232 Slave
Always On Slave
On/off Z-Wave™ control for 2 independent devices
FEATURES: - Z-Wave™ on/off control of 2 individual loads - IP65 rated for outdoor use - Easy set-up and angled plug for better outlet fit - S2 security and Z-Wave™ Plus technology - Supports OTA firmware updates - ETL listed for compliance with North American safety standards SPECS: - Z-Wave™ Frequency: 908.42 MHz (US) - Power: 120 VAC, 60 Hz - Maximum Loads: 960W incandescent, 150W LED bulbs, 15A resistive, 1/3 HP fan motors combined between 2 outlets - Z-Wave™ Range: Up to 300 feet line of sight - Dimensions: 5" tall, 3.5" wide, 1.75" deep - Cord Length: 6.5" - Operating Temperature: 32-104° F (0-40° C) - Installation: Indoor or outdoor use, IP65 rated

Product Image
View configuration parameters (8)
1 - LED Indicator
Decide how the LED indicator behaves depending on the on/off status of the plug. The LED indicator will flash twice to confirm a setting has been changed.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | LED indicator is on when the plug is on, LED indicator is off when the plug is off |
| 1 | 1 | LED indicator is on when the plug is off, LED indicator is off when the plug is on |
| 2 | 2 | LED indicator is always off |
2 - Auto-off Timer Outlet 1
Use this parameter to set the auto turn-off timer for Outlet 1: the time after which you want Outlet 1 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
3 - Auto-off Timer Outlet 2
Use this parameter to set the auto turn-off timer for Outlet 2: the time after which you want Outlet 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
4 - Auto-on Timer Outlet 1
Use this parameter to set the auto turn-on timer for Outlet 1: the time after which you want Outlet 1 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
5 - Auto-on Timer Outlet 2
Use this parameter to set the auto turn-on timer for Outlet 2: the time after which you want Outlet 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
6 - On/Off Status Recovery After Power Failure
Choose the recovery state for your Double Outdoor Plug if a power outage occurs.Size: 1 byte
Default: 2
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | both outlets on the plug automatically turn OFF once power is restored (it ignores the status prior to power outage) |
| 1 | 1 | both outlets on the plug automatically turn ON once power is restored (it ignores the status prior to the power outage) |
| 2 | 2 | both outlets on the plug remember and restore the status prior to the power outage |
7 - Brightness of LED indicator
Set the brightness level of the LED indicator.Size: 1 byte
Default: 2
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | High |
| 1 | 1 | Medium |
| 2 | 2 | Low |
8 - Z-Wave Button Control
Choose if you want to use the physical Z-Wave button on the plug to turn the outlets on or off manually or if you want to disable this function. If this parameter is set to 0 (disabled), you will only be able to turn the outlet on or off remotely using your Z-Wave hub.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Manual control disabled |
| 1 | 1 | Manual control enabled |
Operating instructions (3)
Initiate inclusion (pairing) in the app (or web interface). While the hub is looking for new devices, click the ZWave™ button 3 times as quickly as possible. The LED indicator will start flashing blue to confirm inclusion. mode and turn green for 1 second once inclusion is completed.
1. Bring the plug within direct range of your Z-Wave™ gateway (hub). 2. Put the Z-Wave™ hub into exclusion mode (not sure how to do that? [email protected]). 3. Press and release the Z-Wave™ button 3 times quickly. 4. Your hub will confirm exclusion and the plug will disappear from your controller's device list.
When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. In order to complete the process, make sure the plug is powered, then click the Z-Wave™ button twice and hold it the third time for 10 seconds. The LED indicator will flash green 3 times to confirm a successful reset.
Document (1)
| Type | Name | |
|---|---|---|
| Product Manual | zooz-outdoor-double-plug-zen14-manual.pdf |
Features (6)
| Type | Value(s) |
|---|
Supported notification (1)
| Group | Type |
|---|---|
| Power Management | Over-load status: Over-load detected |