The Ness Z-Wave™ Reed Switch (ZWR) is a miniature battery-powered magnetic reed switch with Z-Wave Plus™ connectivity and hundreds of uses.

View configuration parameters (6)
1 - BASIC_SET Off Delay
The period of time in seconds to send BASIC SET (0) command to Association Group 2 after BASIC_SET(0xFF) command has reported. Range: 0~3600. Default: 10. value = 0 - disable BASIC SET (0) reportSize: 2 bytes
Default: 10
Minimum: 0
Maximum: 3600
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | disabled |
| 1 | 3600 | seconds |
2 - BASIC SET ON Value
This parameter sets the value sent by the BASIC SET ON command to Association Group 2.Size: 1 byte
Default: 255
Minimum: 1
Maximum: 255
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 99 | dim level |
| 255 | 255 | ON for Binary Switch Device |
3 - When To Send BASIC SET ON Command
This parameter is used to select when to send BASIC SET ON Command.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Do not send Basic Set ON Command |
| 1 | 1 | Open, when the sensor and magnet are pulled apart |
| 2 | 2 | Close, when the sensor and magnet are brought together. |
4 - Low battery setting
Report battery low warning message when the battery level reaches this value in percentage.Size: 1 byte
Default: 10
Minimum: 10
Maximum: 50
Possible values
| From | To | Desription |
|---|---|---|
| 10 | 50 |
5 - Battery Scheduled Report Interval
The battery level scheduled report interval time is based on every 30 minutes per kick. The value N related to the time in minutes is N x 30 minutes. Range: 0~120. Default: 12 (12x30 =360 minutes). Value = 0 - Disable Battery level scheduled report.Size: 1 byte
Default: 12
Minimum: 0
Maximum: 120
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable Battery level scheduled report |
| 1 | 120 | N x 30 minutes |
6 - Reed Sensor Green LED Configuration
This parameter is used to set the Green LED to indicate when the reed sensor detects the MAGNET getting close or moving away or both. Disable the Green LED will save the battery life. 0 - Disable Green LED; 1 - Closing; 2 - Opening; 3 - Opening and Closing.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 3
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable Green LED |
| 1 | 1 | Closing |
| 2 | 2 | Opening |
| 3 | 3 | Opening and Closing |
Operating instructions (5)
Inclusion To add the device into the Z-Wave network: 1) Power on device and ensure it has been factory defaulted. 2) Set the primary controller into inclusion mode. 3) Click the Action Button once to enter inclusion mode. Red LED: fast flashing. Inclusion mode can be cancelled by clicking the Action Button again before the controller starts inclusion mode. Red LED stops flashing. 4) If your Z-Wave controller supports S2 Access encryption and DSK, enter the first 5 digits of the DSK located at bottom of the QR image. 5) If Inclusion is successful: Red LED stops fast flashing. Green LED turns on for 2 seconds.
The Exclusion process is the same as Inclusion however your Z-Wave controller must be in Exclusion mode. You may need to refer to your Z-Wave gateway/controller’s instructions for removing devices. Exclusion To remove the device from the Z-Wave network: 1) The device is powered 2) Set the primary controller into Exclusion mode. 3) Click the Action Button once. 4) If Exclusion is successful: Red LED stops fast flashing. Green LED turns on for 2 seconds.
2. Wake-up To manually wake up the ZWR, press and hold the Action Button for 3 seconds until the Blue LED turns on, then release the button.
3. Factory Default To reset Ness ZWR to factory default settings, press and hold the Action Button for at least 20 seconds. Release the button when the Blue LED turns off (20 seconds). The Green LED will flash once to indicate successful reset. Releasing the Action Button while the Blue LED is on cancels the reset process.
Page 7 Ness Z-Wave Reed Switch is a SmartStart enabled device allowing it to be added into a Z-Wave network by scanning its Z-Wave QR Code with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.