The 800 Series Z-Wave Plus® Water Leak Sensor was designed to detect and report leaks to your Z-Wave® hub reliably and quickly so you can prevent potential water damage.

View configuration parameters (8)
3 - LED Light Mode
Set the LED Light Mode.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
41 - LED brightness
Set the LED brightness.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
84 - Reset Factory Default
Reset sensor to factory defaults.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
85 - Alarm sound
Set alarm sound.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
86 - Low Battery Report
Set threshold for Low Battery Report.Size: 1 byte
Default: 10
Minimum: 5
Maximum: 20
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
87 - Low Battery Chirp
Low battery chirp enabled/disabled.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
88 - Low Battery Chirp interval
Change Number of minutes between low battery chirp sound.Size: 1 byte
Default: 1
Minimum: 1
Maximum: 10
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
89 - Status Reporting
Choose when status reports are sent.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 25
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | 0 |
Operating instructions (5)
**Add/Included** into network or **Remove/Exclusion** from network: Quickly press 1x button
**Add/Included** into network or **Remove/Exclusion** from network: Quickly press 1x button
**Wake-up** the device: Quickly press 3x button:
* **Factory Reset**: * Remove Battery. Press and hold the manual button, * reinsert Battery and continue holding the manual button for 3 seconds. to restore the device to the factory [NOTE] Please use this procedure only when the network primary controller is missing or otherwise inoperable.
If you’re using an S2 hub, it will ask you to enter the DSK PIN or scan the QR code printed on the inside of the sensor’s battery cover to complete SmartStart inclusion.
Document (1)
| Type | Name | |
|---|---|---|
| Unknown | ZW1304UserManual-3.pdf |
Features (2)
| Type | Value(s) |
|---|
Supported notification (1)
| Group | Type |
|---|---|
| Water Alarm | Sensor status: Water leak detected |