Shelly Qubino
Wave PM Mini
QMEM-0A1PC16EU
Meter Sensor DT
HW: 01 FW: 10.07:02.02
EFR32ZG23A
7.19.1
0x0460 (1120)
0x0007 (7)
N/A
ZC14-24070437
2024-07-07 16:54:01
N/A
Enhanced End Node 232
Always On End Node
The Device is a small form factor smart power meter, which allows remote monitoring of electric appliances power consumption with a load of up to 16 A.

View configuration parameters (6)
36 - Power report on change - percentage
This parameter determines the minimum change in consumed power that will result in sending a new report to the gateway.Size: 1 byte
Default: 50
Minimum: 0
Maximum: 100
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | reports are disabled |
| 1 | 100 | 1-100% - change in power |
39 - Minimum time between reports
This parameter determines the minimum time that must elapse before a new power report on O (01) is sent to the gateway.Size: 1 byte
Default: 30
Minimum: 0
Maximum: 120
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | reports are disabled |
| 1 | 120 | 1-120 (1-120s) - report interval |
120 - Factory Reset
Reset to factory default settings and removed from the Z-Wave network.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | No action |
| 1 | 1 | Factory reset |
201 - Serial Number 1
This parameter contains a part of device's serial number.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 2147483647
Possible values
Not available
202 - Serial Number 2
This parameter contains a part of device's serial number.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 2147483647
Possible values
Not available
203 - Serial Number 3
This parameter contains a part of device's serial number.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 2147483647
Possible values
Not available
Operating instructions (4)
7.1 Adding the Device to a Z-Wave® network (inclusion) Note! In case of Security 2 (S2) adding (inclusion), a dialog will appear asking you to enter the corresponding PIN Code (5 underlined digits) that are written on the Z-Wave® DSK label on the side of the Device and on the Z-Wave® DSK label inserted in the packaging. IMPORTANT: The PIN Code must not be lost. 7.1.1. SmartStart adding (inclusion) SmartStart enabled products can be added into a Z-Wave® network by scanning the Z-Wave® QR Code present on the Device with a gateway providing SmartStart inclusion. No further action is required, and the SmartStart device will be added automatically within 10 minutes of being switched on in the network vicinity. 1. With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway. 2. Connect the Device to a power supply. 3. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network. 4. Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave® network automatically. 5. The blue LED will be blinking in Mode 2 during the adding process. 6. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network. 7.1.2. Adding (inclusion) with the S button 1. Connect the Device to a power supply. 2. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network. 3. Enable add/remove mode on the gateway. 4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode. 6. The blue LED will be blinking in Mode 2 during the adding process. 7. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network. Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.
7.2 Removing the Device from a Z-Wave® network (exclusion) Note! The Device will be removed from your Z-Wave® network, but any custom configuration parameters will not be erased. 7.2.1. Removing (exclusion) with the S button 1. Connect the Device to a power supply. 2. Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave® network. 3. Enable add/remove mode on the gateway. 4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode. 6. The blue LED will be blinking in Mode 2 during the removing process. 7. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave® network. Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.
7.3 Factory reset 7.3.1. Factory reset general After Factory reset, all custom parameters and stored values (kWh, associations, routings, etc.) will return to their default state. HOME ID and NODE ID assigned to the Device will be deleted. Use this reset procedure only when the gateway is missing or otherwise inoperable. 7.3.2. Factory reset with the S button Note! Factory reset with the S button is possible anytime. 1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 2. Press the S button multiple times until the LED turns solid red. 3. Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset. 4. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s. 5. The blue LED will be blinking in Mode 1 if the Factory reset is successful. 7.3.3. Remote factory reset with parameter with a gateway Factory reset can be done remotely with the settings in Parameter No. 120.
When adding the Device to a Z-Wave network with a gateway supporting Security 2 (S2), the PIN Code of the Z-Wave Device Specific Key (DSK) is required. You can find it on the label on the side of the Device and a copy is inserted in the packaging, which must not be lost. Do not remove the Z-Wave DSK label from the Device. As a backup measure, use the label in the packaging. The first five digits of the key are highlighted or underlined to help the user identify the PIN Code part of the DSK text. The DSK is additionally represented with a QR Code as shown on the image.
Documents (2)
Features (4)
| Type | Value(s) |
|---|
Supported notifications (4)
| Group | Type |
|---|---|
| Heat Alarm | Heat sensor status: Overheat detected |
| Power Management |
|