Zooz
Power Strip
ZEN20 800LR
Binary Switch DT
HW: 04 FW: 04.10
EFR32ZG23A
7.19.3
0x027A (634)
0xA000 (40960)
0xA004 (40964)
ZC14-25030506
2025-03-11 16:43:11
N/A
Enhanced End Node 232
Always On End Node
5 Z-Wave controllable outlets in a single device with 2 USB ports and energy monitoring.

View configuration parameters (37)
1 - Status recover
On/Off status recovery after power failure.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Device remains OFF after power failure. |
| 1 | 1 | Device turns ON after power failure. |
| 2 | 2 | Device returns to the last state before power failure. |
2 - Wattage report threshold
Power wattage report value threshold.Size: 4 bytes
Default: 5
Minimum: 0
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 65535 | Wattage treshold |
3 - Wattage report interval
Seconds for wattage report frequency.Size: 4 bytes
Default: 180
Minimum: 0
Maximum: 2678400
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 2678400 | seconds |
4 - Energy report interval
Seconds for energy report frequency.Size: 4 bytes
Default: 300
Minimum: 0
Maximum: 2678400
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 2678400 | seconds |
5 - Overload protection threshold
Watt value for overload protection.Size: 2 bytes
Default: 1500
Minimum: 0
Maximum: 1500
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 1500 | Watts |
6 - EP1 auto turn off time enable
Enable or disable EP1 auto turn off timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
7 - EP1 auto turn off minutes
Minutes of EP1 turn off timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
8 - EP1 auto turn on time enable
Enable or disable EP1 auto turn on timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
9 - EP1 auto turn on minutes
Minutes of EP1 turn on timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
10 - EP2 auto turn off time enable
Enable or disable EP2 auto turn off timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
11 - EP2 auto turn off minutes
Minutes of EP2 turn off timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
12 - EP2 auto turn on time enable
Enable or disable EP2 auto turn on timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
13 - EP2 auto turn on minutes
Minutes of EP2 turn on timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
14 - EP3 auto turn off time enable
Enable or disable EP3 auto turn off timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
15 - EP3 auto turn off minutes
Minutes of EP3 turn off timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
16 - EP3 auto turn on time enable
Enable or disable EP3 auto turn on timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
17 - EP3 auto turn on minutes
Minutes of EP3 turn on timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
18 - EP4 auto turn off time enable
Enable or disable EP4 auto turn off timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
19 - EP4 auto turn off minutes
Minutes of EP4 turn off timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
20 - EP4 auto turn on time enable
Enable or disable EP4 auto turn on timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
21 - EP4 auto turn on minutes
Minutes of EP4 turn on timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
22 - EP5 auto turn off time enable
Enable or disable EP5 auto turn off timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
23 - EP5 auto turn off minutes
Minutes of EP5 turn off timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
24 - EP5 auto turn on time enable
Enable or disable EP5 auto turn on timer.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable |
| 1 | 1 | Enable |
25 - EP5 auto turn on minutes
Minutes of EP5 turn on timer.Size: 4 bytes
Default: 60
Minimum: 1
Maximum: 65535
Possible values
| From | To | Desription |
|---|---|---|
| 1 | 65535 | minutes |
26 - Manual control output
Enable or disable output manually.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable manual control |
| 1 | 1 | Enable manual control |
27 - LED indicator
Behavior for indicator.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 2
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | LED always off |
| 1 | 1 | LED on when switch is on |
| 2 | 2 | LED on when switch is off |
28 - All Wattage and Energy report
Enable or disable all wattage and energy report.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable all reports |
| 1 | 1 | Enable all reports |
29 - EP1 Wattage and Energy report
Enable or disable EP1 wattage and energy report.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable EP1 reports |
| 1 | 1 | Enable EP1 reports |
30 - EP2 Wattage and Energy report
Enable or disable EP2 wattage and energy report.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable EP2 reports |
| 1 | 1 | Enable EP2 reports |
31 - EP3 Wattage and Energy report
Enable or disable EP3 wattage and energy report.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable EP3 reports |
| 1 | 1 | Enable EP3 reports |
32 - EP4 Wattage and Energy report
Enable or disable EP4 wattage and energy report.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable EP4 reports |
| 1 | 1 | Enable EP4 reports |
33 - EP5 Wattage and Energy report
Enable or disable EP5 wattage and energy report.Size: 1 byte
Default: 1
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable EP5 reports |
| 1 | 1 | Enable EP5 reports |
34 - USB switch report
Enable or disable USB switch report.Size: 1 byte
Default: 0
Minimum: 0
Maximum: 1
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 0 | Disable USB switch report |
| 1 | 1 | Enable USB switch report |
35 - Current report interval
Seconds for current report.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 2678400
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 2678400 | seconds |
36 - Voltage report interval
Seconds for voltagereport.Size: 4 bytes
Default: 0
Minimum: 0
Maximum: 2678400
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 2678400 | seconds |
37 - Current report threshold
Threshold for current report (x 0.1A).Size: 1 byte
Default: 0
Minimum: 0
Maximum: 50
Possible values
| From | To | Desription |
|---|---|---|
| 0 | 50 | N * 0.1A |
Operating instructions (4)
1. Initiate inclusion (pairing) in the app (or web interface). 2. TAP THE CH1 BUTTON 3 TIMES QUICKLY if using traditional Z-Wave inclusion. 3. The LED indicators will blink blue to signal communication.
1. Bring your Z-Wave gateway (hub) close to the switch if possible 2. Put the Z-Wave hub into exclusion mode (not sure how to do that? [email protected]) 3. Tap the CH1 button 3 times quickly (the LED indicator will start blinking blue) 4. Your hub will confirm exclusion and all of the channels (child outlets) and the main device will disappear from your controller''s device list.
If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, click-click-click’n’hold CH1 button for at least 10 seconds. All LED indicators will flash to confirm successful reset. NOTE: All previously recorded activity and custom settings EXCEPT for the kWh record will be erased from the device’s memory.
Scan the QR code on the back of the device if your hub supports SmartStart inclusion.
Document (1)
| Type | Name | |
|---|---|---|
| Unknown | zooz-zen20-800LR-advanced-manual.pdf |
Features (5)
| Type | Value(s) |
|---|
Supported notification (1)
| Group | Type |
|---|---|
| Power Management | Over-current status: Over-current detected |